Elite Generators
Note: A timer and steam head is required for proper operation of the steam generators.
Model | Maximum Cubic Feet | KW | Volts | Phase | Amps | Breaker Size | Wire Size |
---|---|---|---|---|---|---|---|
SW-50E | 100 | 5.5 | 240 | 1 | 21 | 30A | 10AWG |
SW-50-8E | 100 | 5.5 | 208 | 1 | 24 | 30A | 10AWG |
SW-75E | 220 | 7.5 | 240 | 1 | 31 | 40A | 8AWG |
SW-75-8E | 220 | 7.5 | 208 | 1 | 36 | 45A | 8AWG |
SW-90E | 300 | 9.0 | 240 | 1 | 38 | 50A | 8AWG |
SW-90-8E | 300 | 9.0 | 208 | 1 | 43 | 60A | 6AWG |
SW-90-83E | 300 | 9 | 208 | 3 | 25 | 30A | 10AWG |
SW-112E | 400 | 12 | 240 | 1 | 50 | 70A | 4AWG |
SW-112-8E | 400 | 12 | 208 | 1 | 58 | 80A | 4AWG |
SW-112-83E | 400 | 12 | 208 | 3 | 33 | 50A | 8AWG |
Includes Programmable Digital Timer and Temperature Control Assembly, with Gasket, and
White Oval Timer Overlay, 1 25’ Modular Telephone Cable and 1 each 1/2” Steam Head and Escutcheon in choice of finish